More information on the new Canon imageRUNNER ADVANCE C7000/C9000 series of color MFPs:

- the Canon Advanced imageCHIP system, which runs the MFP, actually consists of:
- Main board which works with the scanner to adjust image size, and process the image
- Accelerator board controls the user interface and controls network connectivity
- Riser board connects other two boards together
- 2GB RAM standard with 80GB hard drive
- When the device feels it needs more toner, it unlocks the door to expose the toner. If end user wants to change the toner, and door is not unlocked, end user must go into the control panel and search for an unlock mode in the Settings/Registration menu
- The new Canon pQ toner does not need fuser oil, and replaces the previous “S” toner and “V” toner used in other models
- The waste toner cartridge is replaced on by a service technician and not by customer
- Every 100 pages, the “Real Time Calibration” is activated to improve consistency of image quality
- Unlike other Canon models, these new models have a paper size sensor in the drawers
- Paper drawers, however, still have a push button that has to be activated in order to open drawers
- There are no screening or gloss optimization controls
- Back to front registration is rated at +/- 1.0 millimeter
- Standard generic print controller does not come with either PCL or PostScript print drivers, as these are expensive options. Also need to add 512MB RAM for PS driver.
- Other print controller options are EFI Fiery & MicroPress
- Maximum paper size is 13”x19”
- Can handle up to 300gsm
- Unit slows down when printing on thick media
- Maximum duplex paper weight is 220gsm (this is only 80lb. cover)
- Does not have paper decurling function
- No perfect bind option
- Optional booklet maker can only stitch up to 20 sheets of paper
- The capacity of the output tray is only 25 booklets
- If customer has installed the Professional Puncher, Paper Folding Unit or Paper Deck A1, Canon recommends that a space of 39.4” between back of unit and wall for technician access.